当前位置:首页>日本横河YOKOGAWA

TCInput/RTDInputModule(IsolatedChannels)
These modules receive signals from mV, thermocouple (TC),RTD, and potentiometer (POT).These are isolated between the field and the system as well as between each channel.
They can be used in dual redundant configuration.
These two modules can be used in dual redundant configuration.
Items |
Specifications |
||
Model |
AAT145 |
AAR145 |
|
Numberofinputchannels |
16,isolatedchannels |
16,isolatedchannels |
|
Inputsignal |
TC:JISC1602:1995(*1),IEC584:1995TypeJ,K,E,B(*2),R,S,T,N mV:-100to150mV,-20to80mV |
RTD:JISC1604:1997(*3),IEC751:1995Pt100(3-wiretype) POT:Totalresistance100Ωto10kΩSpanresistance:50%ormoreoftotalresistance |
|
Switchinginputsignals |
TC/mVcanbesetindividuallyforCH1toCH16. |
RTD/POTcanbeselectedindividuallyforCH1to CH16. |
|
Allowableinputvoltage |
±5V |
±5V |
|
Withstandingvoltage |
Betweeninputandsystem:500VAC(forsinglecard:1500VAC),For1minute Betweeninputchannels:200VAC,For1minute |
||
Inputresistance |
PowerON |
1MΩormore |
|
PowerOFF |
1MΩormore |
||
Accuracy |
±40µV |
RTD:±150mΩPOT:±0.2%/FS |
|
Allowabletotalresistanceofsignalsourcepluswiring |
1000Ωorless |
150Ωorless(wiringresistanceperwire)(*4) |
|
Effectofallowablesignalsourceresistance(1000Ω) |
±20µV |
— |
|
Referencejunctioncompensationaccuracy |
±1°C(*5)(6) |
— |
|
Measurementcurrent |
— |
RTD:1mA |
|
Dataupdateperiod |
1s |
||
Burn-out |
Allchannelscanbesettogether. Setting:notavailable/available(UP/DOWN) detectiontime:60s |
||
Temperaturedrift |
±80µV/10°C |
RTD:±0.3Ω/10°CPOT:±0.4%/10°C |
|
Maximumcurrentconsumption |
350mA(5VDC) |
350mA(5VDC) |
|
Weight |
0.3kg |
||
Externalconnection |
Dedicatedcable(KS1) |
Dedicatedcable(KS8/AKB335) |
*1:ModelAAT145isalsoincompliancewithJISC1602:1981.
*2:TypeBdosenotcarryouttemperaturecompensationandcannotmeasureunder44°C.
*3:ModelAAR145isalsoincompliancewithJISC1604:1989(Pt100,JPt100).
*4:WiringresistanceforthesignalcablesofIN£AandIN£Bmustbeidentical.现场数字解决方案
横河电机的现场数字产品
工厂控制系统中的现场总线应用

现场总线功能模块的工程实施与FCS其他功能模块相同。现场总线功能模块和其他FCS功能模块在操作和监视环境方面也是相同的。横河电机DCS的现场总线应用在工程、操作和监视方面没有任何额外的需求。
更多现场总线信息请点击这里。
应用现场总线的最Z大优势是对现场设备的高效维护。横河电机提供资产管理软件包——工厂资源管理器(PRM),用以进行设备管理和诊断。通过PRM,现场总线的优势得以优化,使得整个系统的维护更加高效。
工厂资源管理器(PRM)
PRM通过现场总线收集设备维护信息,将其存储在PRM数据库中。通过现场总线即可进行现场设备的维护。因此维护工程师无需深入偏远地区和危险区域的设备现场,工作效率得到了极大的提高。

审计跟踪
审计跟踪管理在控制和维护系统中是非常重要的。所有由PRM进行的设备维护工作都会被记录和存储下来,检索起来也非常方便。
预见性维护
通过设备管理信息的综合管理,可以预测设备的更新周期和设备故障的发展趋势。这种技术可最小化设备问题对工厂运行的影响,也可以计划和安排维护工作以及零件的采购。
非现场总线设备的解决方案
除现场总线设备外,PRM也可以为已有设备创建数据库。数据库中记录并管理维护信息,以支持工厂中所有设备的整体全面的计划维护。