    供应详情

    当前位置:首页>日本横河YOKOGAWA

    ARM55C-000/BR3

    类别: 日本横河YOKOGAWA
    发布时间: 2021-03-13 10:28:16
    价格: ¥0
    发送联系信息 订购热线:13530116378
    详情
    ARM55C-000/BR3横河ARM55C-000/BR3端子板

    Mechanical Relay Boards (Contact Output)

     

    Models

    ARM55D

    ARM55W ARM55T (with switch)

    ARM55C

     

     

    Usage

     

    Mechanical Relay Dry Contact Output (“a contact (NO))

    (Single / Dual-redundant)

    Mechanical Relay Wet Contact Output (Single / Dual-redundant) AUTO/OFF/ON switch (only for ARM55T)

    Mechanical Relay

    Dry Contack Output

    (“a contact or “b contact (NO or

    NC))

    (Single / Dual-redun or dant) (*6)

    Contact Points

    32-point

    32-point

    32-point

    Terminals for Field Device

    Connection

     

    M4 screws

     

    M4 screws

    M3.5 screws (*5)

    (M4 in power input part)

     

    Modules

    ADV551 (DO: 32-point)

    + ATD5A (Terminal block) ADV561 (DO: 64-point) (*1)

    ADV551 (DO: 32-point)

    + ATD5A (Terminal block) ADV561 (DO: 64-point) (*1)

    ADV551 (DO: 32-point)

    + ATD5A (Terminal block) ADV561 (DO: 64-point) (*1)

     

    Signal Cables

    AKB331 (for 32-point) AKB337 (for 64-point)

    AKB331 (for 32-point) AKB337 (for 64-point)

    AKB331 (for 32-point) AKB337 (for 64-point)

     

    Maximum Load (*2)

    250 V AC: 2 A per point

    30 V DC: 2 A per point

    125 V DC: 0.1 A per point (*3)

    250 V AC: 0.6 A per point

    30 V DC: 0.6 A per point

    125 V DC: 0.1 A per point (*3)

     

    30 V DC: 1.5 A per point

    Minimum Load

    5 V, 10 mA

    5 V, 10 mA

    5 V, 10 mA

    Power Supply Voltage and Current Consumption of Internal Circuit (require external power supply)

     

    24 V DC Max. 0.65 A

     

    24 V DC Max. 0.65 A

     

    24 V DC Max. 0.85 A

     

    Power Supply for Field

    Device

    (require external power supply)

     

     

    -

    Dual-line (supply power per 16- point)

    250 V AC: Max. 9.6 A

    30 V DC: Max. 9.6 A

    125 V DC: Max. 1.6 A

     

     

    -

    Insulation Resistance

    At least 10 M (500 V DC)

    At least 10 M (500 V DC)

    At least 10 M (500 V DC)

     

     

    Withstanding Voltage

    Between field device terminals and cases: 2 kV

    Between 24 V power terminals and cases: 500 V

    Between 24 V power terminals and field device terminals: 2 kV

    Between field device terminals and cases: 2 kV

    Between 24 V power terminals and cases: 500 V

    Between 24 V power terminals and field device terminals: 2 kV

    Between field device terminals and cases: 2 kV

    Between 24 V power terminals and cases: 500 V

    Between 24 V power terminals and field device terminals: 2 kV

    Ambient Temperature and

    Humidity

     

    0 to 50 °C, 10 to 90 %RH

     

    0 to 50 °C, 10 to 90 %RH

     

    0 to 50 °C, 10 to 90 %RH

     

    Standards

    Safety Standard [CSA] (*3) EMC standards [CE Marking], [C-Tick Marking], [KC Marking]

    Safety Standard [CSA] (*3) EMC standards [CE Marking], [C-Tick Marking], [KC Marking]

    EMC standards [CE Marking], [C-Tick Marking], [KC Marking] (*4)

    Size

    W: 482.6 mm x H: 132.5 mm (3U)

    W: 482.6 mm x H: 177 mm (4U)

    W: 482.6 mm x H: 132.5 mm (3U)

    Weight

    2.2 kg

    2.6 kg

    2.2 kg

     

    *1:      Two sets of relay board (ARM55D, ARM55W, ARM55T, or ARM55C) and two sets of signal cable (AKB337) are required for one ADV561.

    *2:      For inductive loads, connect a spark killer (CR network for AC; diode for DC) in parallel with loads.

    *3:      For DC, 30 V or less is the requirement for the Safety Standard [CSA].

    *4:      ARM55C does not conform to Safety Standard [CSA].

    *5:     The applicable size of solderless lug is described below

    DCS培训教材:

    CS3000系统操作说明

    每台HIS在启动后会自动以操作员权限登录,登录后一般都会有一个根据组态而出现的总貌画面。操作员可以使用总貌中的链接进入所在工段,也可以用操作员键盘快捷键进入所在工段。

    1.名词解释:

    1.1过程报.警(Process Alarm):过程报.警该钮显亮,点击出现报.警信息的窗口。

    1.2系统报.(System Alarm):系统报.警时,该钮闪亮,点击弹出系统报.警信息窗口。

    1.3操作员指导信息(Operator Guide Message):有操作员指导信息时,该钮闪亮,点击弹出指导信息窗口。

    1.4 登录信息(User In Monitor):设置用户身份。

    1.5 窗口调用菜单(Window  Call  Menu):调用各种画面。

    1.6 操作菜单(Operation Menu):相关流程图切换按钮。

    1.7 预设窗口菜单(Preset Window Menu):调用预先设置的画面。

    1.8 工具条(Toolbox):显示常用工具条。

    1.9画面导航器(Navigator):各种画面管理器。

    1.10名称输入(Name Input):直接输入仪表位号或画面名称调用画面。

    1.11画面切换(Circulate):在系统画面与通用程序间切换。

    1.12清屏(Clear):关闭所有系统画面。

    1.13消音:消除报.警声。

    1.14拷贝(Copy):打印屏幕上任何东西。

    1.15 OK:确认。