Mechanical Relay Boards (Contact Output)
Models |
ARM55D |
ARM55W ARM55T (with switch) |
ARM55C |
Usage |
Mechanical Relay Dry Contact Output (“a” contact (NO)) (Single / Dual-redundant) |
Mechanical Relay Wet Contact Output (Single / Dual-redundant) AUTO/OFF/ON switch (only for ARM55T) |
Mechanical Relay Dry Contack Output (“a” contact or “b” contact (NO or NC)) (Single / Dual-redun or dant) (*6) |
Contact Points |
32-point |
32-point |
32-point |
Terminals for Field Device Connection |
M4 screws |
M4 screws |
M3.5 screws (*5) (M4 in power input part) |
Modules |
ADV551 (DO: 32-point) + ATD5A (Terminal block) ADV561 (DO: 64-point) (*1) |
ADV551 (DO: 32-point) + ATD5A (Terminal block) ADV561 (DO: 64-point) (*1) |
ADV551 (DO: 32-point) + ATD5A (Terminal block) ADV561 (DO: 64-point) (*1) |
Signal Cables |
AKB331 (for 32-point) AKB337 (for 64-point) |
AKB331 (for 32-point) AKB337 (for 64-point) |
AKB331 (for 32-point) AKB337 (for 64-point) |
Maximum Load (*2) |
250 V AC: 2 A per point 30 V DC: 2 A per point 125 V DC: 0.1 A per point (*3) |
250 V AC: 0.6 A per point 30 V DC: 0.6 A per point 125 V DC: 0.1 A per point (*3) |
30 V DC: 1.5 A per point |
Minimum Load |
5 V, 10 mA |
5 V, 10 mA |
5 V, 10 mA |
Power Supply Voltage and Current Consumption of Internal Circuit (require external power supply) |
24 V DC Max. 0.65 A |
24 V DC Max. 0.65 A |
24 V DC Max. 0.85 A |
Power Supply for Field Device (require external power supply) |
- |
Dual-line (supply power per 16- point) 250 V AC: Max. 9.6 A 30 V DC: Max. 9.6 A 125 V DC: Max. 1.6 A |
- |
Insulation Resistance |
At least 10 MΩ (500 V DC) |
At least 10 MΩ (500 V DC) |
At least 10 MΩ (500 V DC) |
Withstanding Voltage |
Between field device terminals and cases: 2 kV Between 24 V power terminals and cases: 500 V Between 24 V power terminals and field device terminals: 2 kV |
Between field device terminals and cases: 2 kV Between 24 V power terminals and cases: 500 V Between 24 V power terminals and field device terminals: 2 kV |
Between field device terminals and cases: 2 kV Between 24 V power terminals and cases: 500 V Between 24 V power terminals and field device terminals: 2 kV |
Ambient Temperature and Humidity |
0 to 50 °C, 10 to 90 %RH |
0 to 50 °C, 10 to 90 %RH |
0 to 50 °C, 10 to 90 %RH |
Standards |
Safety Standard [CSA] (*3) EMC standards [CE Marking], [C-Tick Marking], [KC Marking] |
Safety Standard [CSA] (*3) EMC standards [CE Marking], [C-Tick Marking], [KC Marking] |
EMC standards [CE Marking], [C-Tick Marking], [KC Marking] (*4) |
Size |
W: 482.6 mm x H: 132.5 mm (3U) |
W: 482.6 mm x H: 177 mm (4U) |
W: 482.6 mm x H: 132.5 mm (3U) |
Weight |
2.2 kg |
2.6 kg |
2.2 kg |
*1: Two sets of relay board (ARM55D, ARM55W, ARM55T, or ARM55C) and two sets of signal cable (AKB337) are required for one ADV561.
*2: For inductive loads, connect a spark killer (CR network for AC; diode for DC) in parallel with loads.
*3: For DC, 30 V or less is the requirement for the Safety Standard [CSA].
*4: ARM55C does not conform to Safety Standard [CSA].
DCS培训教材:
CS3000系统操作说明
每台HIS在启动后会自动以操作员权限登录,登录后一般都会有一个根据组态而出现的总貌画面。操作员可以使用总貌中的链接进入所在工段,也可以用操作员键盘快捷键进入所在工段。
1.名词解释:
1.1过程报.警(Process Alarm):过程报.警该钮显亮,点击出现报.警信息的窗口。
1.2系统报.警(System Alarm):系统报.警时,该钮闪亮,点击弹出系统报.警信息窗口。
1.3操作员指导信息(Operator Guide Message):有操作员指导信息时,该钮闪亮,点击弹出指导信息窗口。
1.4 登录信息(User In Monitor):设置用户身份。
1.5 窗口调用菜单(Window Call Menu):调用各种画面。
1.6 操作菜单(Operation Menu):相关流程图切换按钮。
1.7 预设窗口菜单(Preset Window Menu):调用预先设置的画面。
1.8 工具条(Toolbox):显示常用工具条。
1.9画面导航器(Navigator):各种画面管理器。
1.10名称输入(Name Input):直接输入仪表位号或画面名称调用画面。
1.11画面切换(Circulate):在系统画面与通用程序间切换。
1.12清屏(Clear):关闭所有系统画面。
1.13消音:消除报.警声。
1.14拷贝(Copy):打印屏幕上任何东西。
1.15 OK:确认。