当前位置:首页>日本横河YOKOGAWA

GENERAL
This GS covers the hardware specifications of the Analog I/O Modules (for FIO) that can be installed in the Node Unit for ESB Bus (Local Node) (ANB10S, ANB10D), the Node Unit for ER Bus (Remote Node) (ANR10S, ANR10D) and Compact Field Control Unit (for FIO) (AFF50S, AFF50D, AFV10S, AFV10D).
n STANDARD SPECIFICATIONS
l Current/Voltage Input Modules (Non-Isolated)
Items Specifications Model AAI141 (*1) AAV141 AAV142 AAB141(*1) (*4) Number of input channels 16, non-isolated 16, non-isolated (differential input) 16, non-isolated 16, non-isolated (differential input at voltage input) Input signal 4 to 20 mA DC 1 to 5 V DC (allowable common mode voltage ± 1 V or less) -10 to 10 V DC Voltage input : 1to 5 V DC (allowable common mode voltage ±1 V or less) Current input : 4 to 20 mA DC(*5) Allowable input current/voltage 27 mA ±7.5 V ±13 V Voltage input : ±7.5 V Current input : 25 mA Withstanding voltage — Input resistance Power ON 400 Ω (at 20 mA) to 1000 1 MΩ or more 1 MΩ or more Voltage input : 1 MΩ or more Current input : 290 Ω (at 20 mA) to 450 Ω (at 4 mA) (*6) Power OFF 500 kΩ or more 340 kΩ or more 660 kΩ or more Voltage input : 340 kΩ or more Current input : 500 kΩ or more Accuracy ±16 µA ±4 mV ±20 mV Voltage input : ±4 mV Current input : ±16 μA Data update period 10 ms Step response time 100 ms Transmitter power supply 14.8 V or more (at 20 mA) (*3) 26.4 V or less (at 0 mA) (output current limit: 27 mA) — Setting of 2-wire or 4-wire transmitter For each channel by setting pin — Drift due to ambient temperature change ±16 µA/10 °C ±4 mV/10 °C ±20 mV/10 °C ±0.1 %/10 °C Maximum current consumption 310 mA (5 V DC), 450 mA (24 V DC) 350 mA (5 V DC) 350 mA (5 V DC) 480 mA (5 V DC), 120 mA (24 V DC) Weight 0.2 kg 0.2 kg 0.2 kg 0.3 kg External connection Pressure clamp terminal, KS cable, MIL connector cable KS cable HART communication (*7) Available — — Available (at current input)
These modules mainly receive 4 to 20 mA DC or 1 to 5 V DC standardized signal from 2-wire/4-wire transmitters. They can be used in dual redundant configuration.
Ω (at 4 mA) (*2)
*1: This module does not allow a Zener barrier to be connected. If the module is to be used in intrinsically safe applications, use an isolation barrier.
*2: Viewed from the terminals, module input resistance is, depending on the current flowing:
voltage drop in the input protection circuit
current value
F07E.ai
*3: This voltage is developed between connecting terminals for this module’s 2-wire transmitter. When calculating if transmitter minimum operating voltage requirement will be satisfied, remember to allow for voltage drop in external wiring.
*4: R4.03 or later version supports this module. This module must be used with following FCS. AFG30£, AFG40£, AFG8££, AFF50£, or AFV10£.
*5: Input mode of each channel is selectable by software.
*6: Viewed from the terminals, module input resistance is, depending on the current flowing:
voltage drop in the input protection circuit
F10E.ai
*7: When installing the module with HART function to a remote node, the firmware of EB401 must be Rev 2 or later.
横河AAI141-H03输入模块
CS3000卡件-PW404、CS3000卡件-PW501、CS3000卡件-PW502、CS3000卡件-PW504
CS3000卡件-MRI、CS3000卡件-MRO、CS3000卡件-A1054UY、CS3000卡件-S9600UG
CS3000卡件-AKT201、CS3000卡件-AKT202、CS3000卡件-AKT203、CS3000卡件-AKT211
CS3000卡件-CP151、CS3000卡件-CP332、CS3000卡件-CP332D、CS3000卡件-CP333
CS3000卡件-P333D、CS3000卡件-CP703、CS3000卡件-CP345、CS3000卡件-AIP131
CS3000卡件-RB301、CS3000卡件-RB401、CS3000卡件-VF311、CS3000卡件-PW803
CS3000卡件-S9961UK、CS3000卡件-S9400UK、CS3000卡件-S9765UK、CS3000卡件-AIP601
CS3000卡件-A1096EM、CS3000卡件-AIP261、CS3000卡件-T9070PZ、CS3000卡件-AIP481
CS3000卡件-AMT16M、CS3000卡件-AMT16T、CS3000卡件-ALR111、CS3000卡件-ALR121
CS3000卡件-ALE111、CS3000卡件-ALP111、CS3000卡件-ATA4S、CS3000卡件-ATT4S
AAI141-H50模块横河AAI141-H50模块